Phenolic paper sheets, grade N (general purpose)
- Thicknesses
- 3 to 40 mm
- Colour
- natural; black on request
- Sheet size
- approx. 1070 × 1070 mm
- Insulation class
- E, 120 °C
Grade N phenolic paper is the general purpose paper and phenolic resin laminate: a rigid insulating material used to make punched parts, panels and switchboards for electrical engineering, telecommunications and electronics.
Applications
Grade N is suitable for all applications with no special requirements. It is not recommended for use in hot oil: in that case grade AT phenolic paper is the better choice. For thin punched parts there is grade TR.
Composition
Layers of pure cellulose Kraft paper impregnated with thermosetting phenolic resin, pressed and cured.
Equivalent standards
- CEI EN 60893 - PFCP201
- Type "N", CEI - UNEL standards
- Grade X, NEMA standards
- Type HP 2061, DIN 7735
- MIL - I- 24768/12 - PBM
- Class P1, BS 2572 : 1955
Technical data sheet
| GRADE "N" | |
|---|---|
| Colour | natural / black |
| Insulation class | E, 120 °C |
| Density | 1.4 g/cm3 |
| Thicknesses | Tolerances to UNEL table 02612 |
| Water absorption | 2% |
| Heat shock test (1 h at 160 °C) | good |
| Resistance to mineral oil (72 h at 120 °C) | good |
| Flexural strength | N/cm2 ≥ 13000 |
| Compressive strength | |
| perpendicular to laminations | N/cm2 ≥ 25000 |
| parallel to laminations | N/cm2 ≥ 16000 |
| Impact strength | |
| perpendicular to laminations | N/cm2 ≥ 300 |
| parallel to laminations | N/cm2 ≥ 200 |
| Tensile strength | N/cm2 ≥ 12000 |
| Cleavage strength | N 3000 |
| Rockwell hardness (F scale) | ≥ 30 |
| Voltage test | |
| perpendicular to laminations | kV 40 |
| parallel to laminations | kV ≤ 30 |
| Insulation resistance between pins | MOhm 104 |
| Surface resistance | MOhm 105 |
| Volume resistance | MOhm 105 |
| Flammability, UL 94 (horizontal) | class HB, slow burning |
| Tests carried out on samples: | 10 mm thick |
| Reference standards: | CEI - UNEL |
| Sheet composition: pure cellulose Kraft paper, phenolic resin | |
The data shown are measured on material from normal production and may vary slightly.